EXIDE CORP -- ALL LEAD ACID BATTERIES -- 6140-01-041-0264
===================== Product Identification =====================
Product ID:ALL LEAD ACID BATTERIES
MSDS Date:05/01/1991
FSC:6140
NIIN:01-041-0264
=== Responsible Party ===
Company Name:EXIDE CORP
Address:9176 RED BRANCH RD
City:COLUMBIA
State:MD
ZIP:21045-2059
Country:US
Info Phone Num:301-596-2680
Emergency Phone Num:301-596-2680
CAGE:90660
=== Contractor Identification ===
Company Name:ENERSYS INC
Address:8306PATUXENT RANGE RS SUITE 103
Box:City:JESSUP
State:MD
ZIP:20794-8609
Country:US
Phone:301-381-8500 OR 215-378-0757
CAGE:90660
============= Composition/Information on Ingredients =============
Ingred Name:LEAD (SARA III)
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 60% %
Other REC Limits:NONE SPECIFIED
OSHA PEL:0.05 MG/M3;1910.1025
ACGIH TLV:0.15 MG/M3;DUST 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:ANTIMONY (SARA III)
CAS:7440-36-0
RTECS #:CC4025000
Fraction by Wt: 2% %
Other REC Limits:NONE SPECIFIED
OSHA PEL:0.5 MG/M3
ACGIH TLV:0.5 MG SB/M3; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:ARSENIC (SARA III)
CAS:7440-38-2
RTECS #:CG0525000
Fraction by Wt: 0.2% %
Other REC Limits:NONE SPECIFIED
OSHA PEL:0.5 MG/M3 (AS)
ACGIH TLV:0.01,A1 MG/M3; 9394
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:CALCIUM, METAL
CAS:7440-70-2
RTECS #:EV8040000
Fraction by Wt: 0.2% %
Other REC Limits:NONE SPECIFIED
Ingred Name:TIN
CAS:7440-31-5
RTECS #:XP7320000
Fraction by Wt: 0.2% %
Other REC Limits:NONE SPECIFIED
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3; 9192
Ingred Name:SULFURIC ACID (SARA III)
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 10-30%
Other REC Limits:NONE SPECIFIED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NOT SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION:VAPORS OR MIST MAY CAUSE
SEVERE RESPIRATORY IRRITATION. INHALATION OF DUST OR LEAD DUST OR
FUMES MAY CAUSE IRRATION OF UPPER RESPIRATORY TRACT AND LUNGS.
INGESTION; MAY CAUSE SEVERE IRRITAT ION OF MOUTH, THROAT, ESOPHAGUS
AND STOMACH AND MAY CAUSE ABDOMINAL PAIN, NAUSEA, VOMITING,
DIARRHEA AND CRAMPS.
Explanation of Carcinogenicity:PRODUCT CONTAINS NO INGREDIENTS
CURRENTLY CLASSIFIED AS CARCINOGENIC BY NTP, IARC OR OSHA.
Effects of Overexposure:SEVERE SKIN IRRITATION, DAMAGE TO CORNEA, UPPER
RESPIRATORY IRRITATION, HEADACHE, FATIGUE, ABDOMINAL PAIN, LOSS OF
APPETITE, MUSCULAR ACHES AND WEAKNESS, SLEEP DISTURBANCES AND
IRRITABILITY. EROSION O F TOOTH ENAMEL, INFLAMMATION OF NOSE,
THROAT AND BRONCHIAL TUBES, ANEMIA, NEUROPHATY, PARTICULARLY OF THE
MOTOR NERVES.
Medical Cond Aggravated by Exposure:LUNG DAMAGE AND AGGRAVATED
PULMONARY CONDITIONS, SKIN DISEASE AND SOME FORMS OF KIDNEY, LIVER
AND NEUROLOGIC DISEASE MAY BE AGGRAVATED BY EXPOSURE.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE FROM EXPOSURE, GARGLE, WASH NOSE AND LIPS.
IF BREATHING IS DIFFICULT GIVE OXYGEN. CONSULT A PHYSCIAN.
INGESTION: GIVE LARGE QUANTITIES OF WATER, DO NOT INDUCE VOMITING.
CALL A PHYSC IAN. SKIN: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES, REMOVE ALL CONTAMINATED CLOTHING. EYES: FLUSH
IMMEDIATELY WITH WATER FOR 15 MINUTES. CONSULT A DOCTOR.
===================== Fire Fighting Measures =====================
Lower Limits:4.1 %
Upper Limits:74.2 %
Extinguishing Media:CO2, FOAM, DRY CHEMICAL, HALOGEN
Fire Fighting Procedures:IF BATTERIES ARE ON CHARGE, SHUT OFF POWER.
USE POSITIVE PRESSURE, SCBA, WATER APPLIED TO ELECTROLYTE GENERATES
HEAT AND MAY SPLATTER.
Unusual Fire/Explosion Hazard:HIGHLY FLAMMABLE HYDGROGEN GAS IS
GENERATED DURING CHARGING AND OPERATING OF BATTERIES. KEEP HEAT AND
SPARKS AWAY.
================== Accidental Release Measures ==================
Spill Release Procedures:STOP FLOW OF MATERIAL, CONTAIN/ABSORB SPILLS
WITH DRY SAND, EARTH, OR VERMIVULITE. DO NOT USE COMBUSTIBLE
MATERIALS. DO NOT DISCHARGE UNNEUTRALIZED ACID TO SEWER.
Neutralizing Agent:LIME, SODA ASH OR SODIUM BICARBONATE.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL WELL VENTILATED AREA
WITH IMPERVIOUS SURFACES AND ADEQUATE CONTAINMENT IN THE EVENT OF
SPILLS, ADEQUATE WATER SUPPLY FOR SPILL CONTROL.
Other Precautions:NONE GIVEN
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHEN CONCENTRATION OF SULFURIC ACID MIST ARE
KNOWN TO EXCEED PEL USE NIOSH OR MSHA APPROVED RESPIRATORY
PROTECTION.
Ventilation:LOCAL
Protective Gloves:ACID RESISTANT W/ELBOW LENGTH GAUNTLET
Eye Protection:CHEMICAL GOGGLES OR FACE SHIELD
Other Protective Equipment:ACID RESISTANT APRON. ACID RESISANT CLOTHING
IF CONDITION WARRANT.
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health
IN AREAS WHERE SULFURIC ACID IS HANDLED IN CONCENTRATIONS GREATER THAN
1% EMERGENCY EYE WASHES AND SHOWERS SHOULD BE PROVIDED WITH
UNLIMITED WATER SUPPLY.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:203F,95C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:10 MMHG
Vapor Density:>1
Spec Gravity:1.230-1.350
Evaporation Rate & Reference:<1
Solubility in Water:100%
Appearance and Odor:MANUFACTURED ARTICE NO ODOR
Percent Volatiles by Volume:NIL
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
COMBUSTIBLES AND ORGANIC MATERIALS MAY CAUSE FIRE AND EXPLOSION. ALSO
REACTS WITH STRONG REDUCING AGENTS.
Stability Condition to Avoid:PROLONGED OVERCHARGE, SOURCES OF IGNITION.
Hazardous Decomposition Products:SULFURIC ACID:SULFUR TRIOXIDE, CARBON
MONOXIDE, SULFURIC ACID MIST, SULFUR DIOXIDE, HYDROGEN.
==================== Disposal Considerations ====================
Waste Disposal Methods:PLACE NEUTRALIZED SLURRY INTO SEALED CONTAINERS
AND DISPOSE OF AS HAZARDOUS WASTE AS APPLICABLE. LARGE
WATER-DILUTED SPILLS, AFTER NEUTRALIZATIOM AND TESTING SHOULD BE
MANAGED IN ACCORDANCE WITH APPRO VED LOCAL STATE AND FEDERAL
REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.